Home> News> Requirements for how to correctly install High Pressure Hydrogenation Valve

Requirements for how to correctly install High Pressure Hydrogenation Valve

June 28, 2024

1. A filter should be designed and installed before the High Pressure Hydrogenation Valve to protect the High Pressure Hydrogenation Valve and extend its service life. Before installing the High Pressure Hydrogenation Valve, the pipeline system must be flushed and cleaned to prevent welding slag, oxide scale and other dirt from flowing into the valve and affecting the normal operation of the valve.

Application Of High Pressure Hydrogenation Valve

2. A Special Valve should be installed in front of the High Pressure Hydrogenation Valve, generally installed in front of the filter, to facilitate cutting off the water source during maintenance. In order to ensure the normal maintenance and uninterrupted water supply of the product, a parallel installation method should be adopted. At this time, Special Valve should be installed before and after the High Pressure Hydrogenation Valve.
3. When using liquid, the filter should use a 40-mesh filter screen, and when using gas, an 80-mesh filter screen should be used.
4. If a pressure gauge is set before and after the High Pressure Hydrogenation Valve, the pressure gauge should be kept at a distance of more than 5DN from the inlet or outlet of the High Pressure Hydrogenation Valve.
5. When used for gas, because the volume behind the High Pressure Hydrogenation Valve expands, please use an expansion tube, and the outlet pipe should be large.
6. When using liquid, use straight pipes as much as possible. The length of the straight pipe should be 10~20 times the valve diameter (lower 500mm)
7. A flexible joint and a discharge pipe should be set at the outlet of the High Pressure Hydrogenation Valve to facilitate installation and maintenance.
8. The failure of the High Pressure Hydrogenation Valve in the pipeline is mainly caused by foreign matter, so the pipeline should be fully cleaned before the fluid passes through the High Pressure Hydrogenation Valve (about 30 minutes).
9. The High Pressure Hydrogenation Valve can be installed vertically or horizontally as shown in the figure. During installation, attention should be paid to the inlet and outlet direction of the High Pressure Hydrogenation Valve, which cannot be reversed.
Contact Us

Author:

Mr. Jim

Phone/WhatsApp:

+8613193149443

Popular Products
You may also like
Related Information
Top 10 China Universal Throttle Valve Manufacturers

The Universal Throttle Valve caters to a wide consumer market, from automotive enthusiasts looking to upgrade their performance vehicles to industrial manufacturers seeking reliable and efficient...

Top 10 Anti Coking Ball Valve Manufacturers

Introducing the revolutionary Anti Coking Ball Valve - Say goodbye to clogs and build-up in your pipelines! Our innovative design prevents coke formation, ensuring smooth operation and increased...

Top 10 Most Popular Chinese Wafer soft seal butterfly valve Brands

The wafer soft seal butterfly valve consumer market is growing rapidly due to its high performance and durability. Companies in industries such as water treatment, oil and gas, and chemical...

China Top 10 Multi-way Distribution Valve Brands

A multi-way distribution valve is a type of valve that allows for the distribution of fluids or gases in multiple directions. These valves are commonly used in industrial applications where precise...

Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be betwwen 20-8000 characters

Contact Us

Author:

Mr. Jim

Phone/WhatsApp:

+8613193149443

Popular Products
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send